/* * * Copyright (C) 2015, Open Connections GmbH * All rights reserved. See COPYRIGHT file for details. * * This software and supporting documentation are maintained by * * OFFIS e.V. * R&D Division Health * Escherweg 2 * D-26121 Oldenburg, Germany * * * Module: dcmiod * * Author: Michael Onken * * Purpose: Class for managing the Enhanced US Series Module * */ #ifndef MODENHUSSERIES_H #define MODENHUSSERIES_H #include "dcmtk/config/osconfig.h" #include "dcmtk/ofstd/ofmem.h" #include "dcmtk/ofstd/ofvector.h" #include "dcmtk/ofstd/ofoption.h" #include "dcmtk/dcmiod/iodrules.h" #include "dcmtk/dcmiod/iodmacro.h" #include "dcmtk/dcmiod/modbase.h" /** Class representing the Enhanced Ultrasound Series Module: * * Notation: "Attribute name: (VR, VM, Requirement Type)" * Modality: (CS, 1, 1) * Referenced Performed Procedure Step Sequence: (SQ, 1, 1C) * > SOP Instance Reference Macro * Performed Protocol Code Sequence: (SQ, 1, 1C) * > Code Sequence Macro * Not yet explicitly supported: * ---------------------------------------------- * > Protocol Context Sequence: (SQ, 1-n, 3) * >> Content Item Macro * >> Content Item Modifier Sequence: (SQ, 1-n, 3) * >>> Content Item Macro * ---------------------------------------------- * Performed Protocol Type: (CS, 1, 1C) */ class DCMTK_DCMIOD_EXPORT IODEnhancedUSSeriesModule : public IODModule { public: /** Constructor * @param item The item to be used for data storage. If NULL, the * class creates an empty data container. * @param rules The rule set for this class. If NULL, the class creates * one from scratch and adds its values. */ IODEnhancedUSSeriesModule(OFshared_ptr item, OFshared_ptr rules); /** Constructor */ IODEnhancedUSSeriesModule(); /** Destructor */ virtual ~IODEnhancedUSSeriesModule(); /** Resets rules to their original values */ virtual void resetRules(); /** Get name of module ("EnhancedUSSeriesModule") * @return Name of the module ("EnhancedUSSeriesModule") */ virtual OFString getName() const; /** Read data into this module from given item * @param source The item to read from * @param clearOldData If OFTrue, old data in this module is cleared first (default: OFTrue) * @return EC_Normal if reading was successful, error otherwise */ virtual OFCondition read(DcmItem& source, const OFBool clearOldData = OFTrue); /** Write this module to given item * @param destination The item to write to * @return EC_Normal if writing was successful, error otherwise */ virtual OFCondition write(DcmItem& destination); /** Get Modality, always returns "US" * @param value Reference to variable in which the value should be stored * @param pos Index of the value to get (0..vm-1), -1 for all components * @return EC_Normal if successful, an error code otherwise */ virtual OFCondition getModality(OFString &value, const signed long pos = 0) const; /** Get Referenced Performed Procedure Step * @return Reference to the Referenced Performed Procedure Step information */ virtual SOPInstanceReferenceMacro& getReferencedPPS(); /** Get Performed Protocol Code * @return Reference to the Performed Protocol information */ virtual CodeSequenceMacro& getPerformedProtocolCode(); /** Get Performed Protocol Type * @param value Reference to variable in which the value should be stored * @param pos Index of the value to get (0..vm-1), -1 for all components * @return EC_Normal if successful, an error code otherwise */ virtual OFCondition getPerformedProtocolType(OFString &value, const signed long pos = 0) const; private: /// The name of this module ("EnhancedUSSeriesModule") static const OFString m_ModuleName; /// Referenced Performed Procedure Step Sequence SOPInstanceReferenceMacro m_ReferencedPerformedProcedureStep; /// Performed Protocol Code Sequence (so far, without optional data) CodeSequenceMacro m_PerformedProtocolCode; }; #endif // MODENHUSSERIES_H